This specific tender is managed via the new supplier portal system of UNDP Quantum. If you are interested in submitting a bid for this tender, you must subscribe following the instructions in the user guide. If you have not registered a profile with this system, you can do so by following the link for Supplier Registration.
If you already have a supplier profile, please access the negotiation using quicklink or please login to the Supplier Portal, then search for the negotiation using the reference number UNDP-ZWE-02083,1, following the instructions in the user guide.
Introduction
SCOPE OF WORK
General Obligations
The firm shall:
· Deploy a sufficient team of qualified specialists to complete all preventive maintenance within the contract period.
· Replace worn or defective components using genuine or manufacturer-approved spare parts only. Equivalent-specification parts may be used only with prior written approval from UNDP.
· Use calibrated test instruments for all measurements and document all findings, adjustments, faults, parts replaced and post-service verification results.
· Submit all reports, job cards and deliverables to UNDP (primary recipient) with copies to MoHCC Directorate of Laboratory Services.
· Comply with facility infection prevention and control (IPC) protocols and applicable HSE regulations at all times.
Refrigerator – Preventive Maintenance
Scope: 213 refrigerators (blood bank, pharmaceutical and general laboratory type) at designated facilities
For each refrigerator, the firm shall:
The activities listed below constitute the mandatory minimum maintenance standard. All activities shall be performed on every refrigerator unit. No alternative methodology should be proposed.
· Clean condenser coils and fins using compressed air or appropriate cleaning tools; clean evaporator components as accessible.
· Inspect and clean condenser fan motor and blades; verify correct airflow direction and fan rotation.
· Inspect door gaskets for tears, gaps, hardening or loss of seal; replace defective gaskets.
· Inspect door hinges, closers and locks; adjust or replace as required.
· Inspect thermostat/temperature controller; verify set-point accuracy against a calibrated reference thermometer; record ambient temperature, set-point and actual internal temperature.
· Inspect refrigerant system for leaks using an approved leak detector; record refrigerant type and action taken.
· Check and clean drainage system, drip tray and drain tube; ensure drainage is unobstructed.
· Inspect electrical connections, power cable, compressor capacitor, start relay and overload protector.
· Test temperature alarms (where fitted) for functionality and set-point accuracy.
· Verify compressor start and run performance; record compressor run and cycle characteristics.
· Clean interior and exterior surfaces; inspect for corrosion, damage or mould.
· Record all measurements on the approved refrigerator service checklist.
Cold Room – Preventive Maintenance
Scope: 2 cold rooms (NMRL, Harare and Chinhoyi Provincial Hospital Laboratory)
For each cold room, the firm shall:
The activities listed below constitute the mandatory minimum maintenance standard. All activities shall be performed on every cold room. No alternative methodology shall be proposed.
· Inspect refrigeration plant (compressor, condenser, evaporator) for leaks, performance and condition.
· Clean condenser and evaporator coils and fans; verify correct refrigerant charge.
· Inspect and test door seals, hinges, closers, locks and curtain strips for integrity; replace defective seals.
· Inspect floor drain and drainage system for blockage.
· Verify temperature stability: record temperature at multiple points inside the cold room over a minimum 30-minute observation period; verify alarm set-points.
· Inspect and test temperature alarms and data loggers (where fitted).
· Inspect electrical panel, wiring, contactors, capacitors and earthing.
· Record all measurements and findings on the approved cold room service checklist.
Condition Assessment and Priced Bill of Quantities (BOQ)
· Conduct a thorough physical inspection and functional assessment of every refrigerator and cold room unit at all designated facilities.
· Document the condition status of each unit (Functional / Requires Service / Requires Repair / Non-functional) with supporting technical findings and measurement data.
· Prepare a consolidated, itemised Priced Bill of Quantities (BOQ) listing all units requiring corrective maintenance or parts replacement, with unit descriptions, quantities, and unit/total costs in USD.
· No corrective work shall be executed under this contract without separate written authorisation from UNDP. The Priced BOQ is a planning and authorisation document only.